Lifting Operation
RA-2026-I2Vdt96G Completed📄 Document Management
Upload documents for different statusesClick or drag to upload document for completed status
Supported: PDF, DOC, DOCX, Excel (Max 10MB)
No documents uploaded yet
Risk Assessment Matrix
| SN | Activity | Hazard | Consequence | Groups Exposed | Controls | Initial Risk | Additional Controls | Residual Risk | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 1 |
Mobilization and Site Access of Heavy Mobile Cranes into High-Voltage Substation Yard
|
- Subsurface collapse of unverified backfilled utility corridors
- Overhead encroachment with energized 132kV/400kV transmission lines
- Collision with existing live substation infrastructure, cable risers, and perimeter fencing
- Soft shoulder roll-over on unpaved substation perimeter haul roads
- Tail-swing entrapment of site personnel against blast walls or switchgear buildings
- Brake or steering failure during steep ramp descent into GIS basement bays
|
- Fatal crush injuries and catastrophic poly-trauma
- Uncontrolled electrical flashover and third-degree arc-flash burns
- Severe structural and equipment damage exceeding millions of dollars
- Complete electrical blackout to adjacent distribution grids
- Total crane overturn leading to operator entrapment and death
|
Crane Operator, Rigging Supervisor, Banksman, Substation Commissioning Engineers, Civil Subcontractors
|
- Implement ADOSH-compliant Electrical Isolation and Access Permit to Work (PTW) prior to crane entry
- Conduct Ground Penetrating Radar (GPR) scan and verify civil compaction test reports (CBR > 15%, compaction >= 95% MDD)
- Enforce physical goalposts and non-conductive height limiters set at minimum 10m clearance from energized overhead lines
- Provide dedicated, ADOSH-certified banksman with high-visibility red vest and whistle for constant guiding
- Establish exclusion zones with rigid orange plastic water-filled barriers along the mobilization corridor
- Mandatory pre-entry mechanical inspection by Plant Inspector including brake, steering, and pneumatic lines
- Limit mobilization speed inside the electrical yard strictly to a maximum of 10 km/h
- Ensure 3rd-party calibration and inspection certificate (EIAC/DAC approved) is verified for crane and driver
|
P
4
×
S
5
20
|
- Install proximity warning radar and 360-degree blind-spot camera systems on mobile cranes
- Conduct dedicated pre-mobilization toolbox talk (TBT) highlighting live equipment boundaries
- Assign a dedicated Senior Electrical Safety Escort Officer for all movements inside the compound
- Comply with ISO 45001:2018 – Occupational Health and Safety Management Systems
- Comply with ILO Convention C155 – Occupational Safety and Health
|
P
2
×
S
3
6
|
|
| 2 |
Ground-Bearing Capacity Assessment & Outrigger Pad Setup on Compacted Substation Yard
|
- Punch-through of crane outrigger jacks through concealed electrical duct banks
- Outrigger placement on uncompacted backfill or void pockets near basement retaining walls
- Asymmetrical leveling causing outrigger cylinder seal blow-out
- Structural rupture of buried water drainage or fire deluge pipeline networks
- Inadequate footprint area of outrigger wooden/steel spreader mats
- Subsidence due to subterranean water table fluctuations or soil liquifaction
|
- Crane destabilization leading to sudden structural overturn
- Destruction of critical sub-surface medium and high-voltage feeder cables
- Fatal crushing of banksman or riggers stationed within outrigger slew zone
- Extensive crane structural boom buckling and torsional collapse
- Prolonged project delay and environmental contamination from hydraulic oil spills
|
Crane Operator, Riggers, Appointed Lifting Supervisor, Geotechnical Field Technicians
|
- Conduct comprehensive plate load testing to verify minimum allowable ground bearing capacity (minimum 250 kPa)
- Cross-reference updated As-Built utility drawings and complete electro-magnetic underground pipe/cable locator scans
- Ensure outrigger spreaders are engineered steel mats or certified hardwood timber mats sized >= 3 times the outrigger shoe area
- Verify all outriggers are 100% fully extended and locked with mechanical retaining pins before lifting
- Maintain a minimum set-back clearance distance equal to 1.5 times the trench depth from any open excavation or trench
- Verify crane chassis levelness using the internal electronic spirit level ensuring zero-degree incline (< 0.5% tolerance)
- Deploy ultrasonic or calibrated load cells under each outrigger pad to monitor reaction forces in real time
- Stop all positioning works immediately if soil settlement exceeds 5mm during dry-run functional test
|
P
4
×
S
5
20
|
- Utilize engineered modular interlocking composite outrigger pads with non-slip surfaces
- Perform multi-stage test lift with a 110% dummy test load to confirm ground reaction before actual pick
- Issue documented Lift Plan signed off by an ADOSH-registered Class-A Lifting Engineer
- Comply with ISO 45001:2018 – Occupational Health and Safety Management Systems
- Comply with ILO Convention C155 – Occupational Safety and Health
|
P
2
×
S
3
6
|
|
| 3 |
Crane Telescopic Boom Assembly and Heavy Jib Rigging near Live Transmission Lines
|
- Induction of high-voltage static charge into crane boom structure
- Accidental boom extension entering safe clearance envelope of 400kV lines (less than 8 meters)
- Pinch point and crushing hazards during insertion of jib locking pins
- Dropped rigging accessories, tools, or pin hammers from elevated boom sections
- Uncontrolled pivoting of fly-jib section during manual pin unlatching
- Structural failure of boom extension cylinders due to hydraulic air entrapment
|
- Electrocution of riggers on ground touching crane chassis
- Severe finger/hand amputations and crush fractures during pin insertion
- Fatal impact injuries from dropped pins or structural boom elements from height
- Catastrophic flashover causing major electrical explosion on national grid
- Boom buckling leading to complete structural failure
|
Rigging Crew, Mobile Crane Operator, Banksman, Electrical Safety Observer
|
- Secure Electrical Outage Clearance (Sanction for Test / Sanction to Work) where practicable or maintain 8m absolute clearance
- Ground crane chassis directly to substation grounding grid via minimum 70mm² copper bonding jumpers
- Riggers must utilize 100% tie-off safety harnesses attached to engineered lifelines during high boom work
- Establish an exclusion perimeter of 1.5 times boom length demarcated with red warning tape and warning signage
- Utilize pneumatic/hydraulic pin pushers to insert locking pins instead of manual sledgehammers
- All tools must be 100% tethered using certified elastic tool lanyards to prevent dropped objects
- Employ an independent, dedicated Electrical Observer with air horn and authority to stop works immediately
- Perform boom extension functions at low operating throttle under direct oversight of Lifting Supervisor
|
P
4
×
S
5
20
|
- Install automated 3D virtual wall limiters (RCI/LMI) programmed to prohibit boom rotation toward live overhead bays
- Provide boom-tip electro-static field detectors with audible cab alarms to notify operator of field buildup
- Pre-rig all fly-jib elements on ground level before elevation using dedicated auxiliary mobile crane
- Comply with ISO 45001:2018 – Occupational Health and Safety Management Systems
- Comply with ILO Convention C155 – Occupational Safety and Health
|
P
1
×
S
3
3
|